           PRODOTTI                              UNITÀ DI   VORT HR 260 DH  VORT HR 260 DH RC  VORT HR 500 DH  VORT HR 500 DH RC
           CODICE                                MISURA        45091        45092        45093        45094
           ALIMENTAZIONE                          V/Hz        230/50        230/50       230/50       230/50
           POTENZA ASSORBITA VENTILATORE MANDATA    W         10/30/86     10/30/86     30/60/130    30/60/130
                                               (min/nom/max)
           POTENZA ASSORBITA VENTILATORE RIPRESA    W         11/22/43     11/22/43     22/44/68      22/44/68
                                               (min/nom/max)
           POTENZA FRIGO TOTALE IN AMBIENTE        W           1380         1380          2820         2820

           POTENZA NOMINALE ASSORBITA COMPRESSORE   W          340           340          480          480
           POTENZA TERMICA INVERNALE RECUPERATA    W           950           950          1850         1850
           TIPO DI REFRIGERANTE                                R134A        R134A        R134A         R134A

           CAPACITÀ DI DEUMIDIFICAZIONE UTILE     l/24h        30.1          30.1         61.8         61.8
           EFFICIENZA NOMINALE ESTIVA RECUPERATA   %            70           70           70            70

           EFFICIENZA NOMINALE INVERNALE RECUPERATA  %          90           90           90            90
                                                   kPA
           PERDITE DI CARICO CIRCUITO IDRAULICO                 38           38           35            35
                                                  (nom)
                                                   l/h
           PORTATA D’ACQUA BATTERIA                          150/250/400  150/250/400  200/350/600  200/350/600
                                               (min/nom/max)
           PORTATA D’ARIA MANDATA ESTIVA          m /h         260           260          500          500
                                                   3
           PORTATA D’ARIA MANDATA INVERNO         m /h         0-130        0-130        0-250         0-250
                                                   3
           POTENZA SONORA                         Lw dB(A)      47           47           52            52

           PRESSIONE SONORA                     Lp dB(A) 3m     39           39           44            44
                                                   Pa
           PREVALENZA UTILE VENTILATORE DI MANDATA            50/140        50/140       50/140       50/140
                                                (nom/max)
                                                   Pa
           PREVALENZA UTILE VENTILATORE DI RIPRESA            50/140        50/140       50/140       50/140
                                                (nom/max)
           PESO                                    Kg           60           60           80            80