FAULT CAUSE REMEDY
Q PROFESSIONAL RANGE
ALL THE FITTINGS ARE PROTECTED FROM STAINLESS STEEL FILTERS IN THE INLET
IT IS IMPORTANT BLEED THE PIPES BEFORE THE INSTALLATION
A 2509 A 2595 A 2514 A 2516/2 A 2591 fibre
complete flow mixing and device stainless hot water mixing and stainless washer
adjuster shutting-off steel spring shutting-off device steel filter
device
Outlet
A 2517
A 2591 A 2560/2 A 2594 hot water A 2590
inlet cold stainless flat seal mixing body and stainless inlet hot
water steel filter washer hot water seal set steel spring water
the tap or the mixer leaks there is a foreign body stopped on the flat seal remove the fitting and clean carefully the flat
washer washer A 2560/2 of the mixing device
A 2595. If the washer is worn-out use the
other side, rarely it is to replace because the
closing happen always delicately
the mixer do not supply sufficient hot water inlet hot water filter is half-obstructed clean the filter
hot water mixing device A 2516/2 obstructed remove the hot water inlet A 2590 and clean
the device
locking plates of the stop device in the wrong if the hot water is obtained only pressing the
position pedal it is necessary adjust the locking plates
position.
See the previous indications
in the suspended models the pedal do not provide the installation
make the complete stroke at 15 cm. from the floor