CERTIFICAZIONI DI PRODOTTO











































            CERTIFICATO SOLAR KEYMARK                               CERTIFICATO SOLAR KEYMARK








                          Annex to Solar Keymark Certificate                      Annex to Solar Keymark Certificate
                                                     Page 1/2                                              Page 2/2
                                       Licence Number  SC0140-18         Annex to Solar Keymark Certificate  Licence Number  SC0140-18
                Annex to Solar Keymark Certificate - Summary of EN 12975-2
                                       Date issued  2018-03-16           Supplementary Information   Issued  2018-03-16
                Test Results
                                       Issued by  RISE                    ŶŶƵĂů ĐŽůůĞĐƚŽƌ ŽƵƚƉƵƚ ŝŶ ŬtŚͬĐŽůůĞĐƚŽƌ Ăƚ ŵĞĂŶ ĨůƵŝĚ ƚĞŵƉĞƌĂƚƵƌĞ ੥ m , based on EN 12975-2 test results
                Licence holder  Cordivari S. R. L.  Country Italy              Standard Locations  Athens  Davos  Stockholm  Würzburg
                Brand ;ŽƉƚŝŽŶĂůͿ   sd  Web  ŚƚƚƉ͗ͬͬǁǁǁ͘ĐŽƌĚŝǀĂƌŝ͘ŝƚͬ     Collector name  ੥ m 25°C  50°C  75°C  25°C  50°C  75°C  25°C  50°C  75°C  25°C  50°C  75°C
                Street, Number  ŽŶĂ /ŶĚƵƐƚƌŝĂůĞ WĂŐůŝĂƌĞ ʹ ϲϰϬϮϬ ŵŽƌƌŽ Ě͛ŽƌŽ   E-mail  ŝŶĨŽΛĐŽƌĚŝǀĂƌŝ͘ŝƚ   sdϭϬ  1 998 1 716 1 435 1 682 1 418 1 171 1 212  992  796  1 304 1 069  854
                Postcode, City  dĞƌĂŵŽ  Tel  +39 085 80401                sdϭϱ       2 965 2 546 2 129 2 496 2 105 1 738 1 798 1 472 1 181 1 935 1 586 1 267
                Collector Type          ǀĂĐƵĂƚĞĚ ƚƵďƵůĂƌ ĐŽůůĞĐƚŽƌ
                                           Power output per collector
                                           'ď с ϴϱϬ tͬŵϸ͖ 'Ě с ϭϱϬ tͬŵϸ
                             Gross  area (A G )  Gross  length  Gross  width   Gross  height  0 K  10 K  30 K ੥ŵ Ͳ ੥Ă 50 K  70 K  64 K
                Collector name   m²  mm  mm  mm  W  W  W  W  W  W
                CVT10        2,17  1 917  1 130  133  1 175  1 147  1 088  1 021  947  970
                CVT15        3,22  1 917  1 680  133  1 743  1 703  1 614  1 515  1 406  1 440
                                         0  0  0  0  0  0
                                         0  0  0  0  0  0                 ŶŶƵĂů ŽƵƚƉƵƚ ƉĞƌ ŵϸ ŐƌŽƐƐ ĂƌĞĂ  921  791  661  775  654  540  558  457  367  601  493  393
                                         0  0  0  0  0  0                &ŝdžĞĚ Žƌ ƚƌĂĐŬŝŶŐ ĐŽůůĞĐƚŽƌ  &ŝdžĞĚ ;ƐůŽƉĞ с ůĂƚŝƚƵĚĞ Ͳ ϭϱΣ͖ ƌŽƵŶĚĞĚ ƚŽ ŶĞĂƌĞƐƚ ϱΣͿ
                                         0  0  0  0  0  0                 ŶŶƵĂů ŝƌƌĂĚŝĂƚŝŽŶ ŽŶ ĐŽůůĞĐƚŽƌ ƉůĂŶĞ  ϭϳϲϱ ŬtŚͬŵϸ  ϭϳϭϰ ŬtŚͬŵϸ  ϭϭϲϲ ŬtŚͬŵϸ  ϭϮϰϰ ŬtŚͬŵϸ
                                         0  0  0  0  0  0                DĞĂŶ ĂŶŶƵĂů ĂŵďŝĞŶƚ Ăŝƌ ƚĞŵƉĞƌĂƚƵƌĞ   18,5°C  3,2°C  7,5°C  9,0°C
                                         0  0  0  0  0  0                 ŽůůĞĐƚŽƌ ŽƌŝĞŶƚĂƚŝŽŶ Žƌ ƚƌĂĐŬŝŶŐ ŵŽĚĞ   ^ŽƵƚŚ͕ ϮϱΣ  ^ŽƵƚŚ͕ ϯϬΣ  ^ŽƵƚŚ͕ ϰϱΣ  ^ŽƵƚŚ͕ ϯϱΣ
                                         0  0  0  0  0  0                dŚĞ ĐŽůůĞĐƚŽƌ ŝƐ ŽƉĞƌĂƚĞĚ Ăƚ ĐŽŶƐƚĂŶƚ ƚĞŵƉĞƌĂƚƵƌĞ ੥ŵ ;ŵĞĂŶ ŽĨ ŝŶͲ ĂŶĚ ŽƵƚůĞƚ ƚĞŵƉĞƌĂƚƵƌĞƐͿ͘ dŚĞ ĐĂůĐƵůĂƚŝŽŶ ŽĨ ƚŚĞ ĂŶŶƵĂů
                                         0  0  0  0  0  0                ĐŽůůĞĐƚŽƌ ƉĞƌĨŽƌŵĂŶĐĞ ŝƐ ƉĞƌĨŽƌŵĞĚ ǁŝƚŚ ƚŚĞ ŽĨĨŝĐŝĂů ^ŽůĂƌ <ĞLJŵĂƌŬ ƐƉƌĞĂĚƐŚĞĞƚ ƚŽŽů ^ĐĞŶŽĐĂůĐ sĞƌ͘ ϱ͘Ϭϭ ;DĂƌĐŚ ϮϬϭϲͿ͘   ĚĞƚĂŝůĞĚ
                                         0  0  0  0  0  0                ĚĞƐĐƌŝƉƚŝŽŶ ŽĨ ƚŚĞ ĐĂůĐƵůĂƚŝŽŶƐ ŝƐ ĂǀĂŝůĂďůĞ Ăƚ ǁǁǁ͘ƐŽůĂƌŬĞLJŵĂƌŬ͘ŽƌŐͬƐĐĞŶŽĐĂůĐ
                                         0  0  0  0  0  0                              Additional Information
                                         0  0  0  0  0  0                 ŽůůĞĐƚŽƌ ŚĞĂƚ ƚƌĂŶƐĨĞƌ ŵĞĚŝƵŵ  tĂƚĞƌͲ'ůLJĐŽůĞ
                                         0  0  0  0  0  0                ,LJďƌŝĚ dŚĞƌŵĂů ĂŶĚ WŚŽƚŽ sŽůƚĂŝĐ ĐŽůůĞĐƚŽƌ  EŽ
                Power output per m² gross area  541  529  501  471  437  447  dŚĞ ĐŽůůĞĐƚŽƌ ŝƐ ĚĞĞŵĞĚ ƚŽ ďĞ ƐƵŝƚĂďůĞ ĨŽƌ ƌŽŽĨ ŝŶƚĞŐƌĂƚŝŽŶ  EŽ
                Performance parameters test method  ^ƚĞĂĚLJ ƐƚĂƚĞ Ͳ ŽƵƚĚŽŽƌ  dŚĞ ĐŽůůĞĐƚŽƌ ǁĂƐ ƚĞƐƚĞĚ ƐƵĐĐĞƐƐĨƵůůLJ ĂĐĐŽƌĚŝŶŐ ƚŽ  E /^K ϵϴϬϲ͗ϮϬϭϯ ƵŶĚĞƌ ƚŚĞ ĨŽůůŽǁŝŶŐ ĐŽŶĚŝƚŝŽŶƐ͗
                Performance parameters (related to AG)  ɻϬ͕ŚĞŵ  a1  a2    ůŝŵĂƚĞ ĐůĂƐƐ ; ͕   Žƌ  Ϳ     C    --
                Units           -  W/(m²K) W/(m²K²)                      DĂdžŝŵƵŵ ƚĞƐƚĞĚ ƉŽƐŝƚŝǀĞ ůŽĂĚ  2860  WĂ
                Test results    0,541  1,212  0,004  0,180  0,000  0,000  0,910  DĂdžŝŵƵŵ ƚĞƐƚĞĚ ŶĞŐĂƚŝǀĞ ůŽĂĚ  -  WĂ
                                                                         ,Ăŝů ƌĞƐŝƐƚĂŶĐĞ ƵƐŝŶŐ ƐƚĞĞů ďĂůů ;ŵĂdžŝŵƵŵ ĚƌŽƉ ŚĞŝŐŚƚͿ  0,8  m
                Incidence angle modifier test method  YƵĂƐŝ ĚLJŶĂŵŝĐ Ͳ ŽƵƚĚŽŽƌ
                Bi-directional incidence angle modifiers  zĞƐ                         Energy Labelling Information
                Incidence angle modifier   ŶŐůĞ  10°  20°  30°  40°  50°  60°  70°  80°  90°  ZĞĨĞƌĞŶĐĞ  ƌĞĂ͕   ƐŽů  (m 2 ) Data required for CDR (EU) No 811/2013 - Reference Area A sol
                Transversal  K ɽd͕ĐŽůů  1,03  1,05  1,18  0,00            sdϭϬ         2,17   ŽůůĞĐƚŽƌ ĞĨĨŝĐŝĞŶĐLJ ;ɻ ĐŽů )  49  %
                Longitudinal  K ɽ>͕ĐŽůů    0,95      0,00                 sdϭϱ         3,22  ZĞŵĂƌŬ͗   ŽůůĞĐƚŽƌ ĞĨĨŝĐŝĞŶĐLJ ;ɻ col ) is defined in CDR (EU) No
                Heat transfer medium for testing  tĂƚĞƌ                                    811/2013 as collector efficiency of the solar collector at a
                Flow rate for testing (per gross area, A G )  ĚŵͬĚƚ  0,020 ŬŐͬ;ƐŵϸͿ        temperature difference between the solar collector and the
                Maximum temperature difference for thermal performance calculations  ;੥ m Ͳ੥ a ) max  64  K  surrounding air of 40 K and a global solar irradiance of 1000
                ^ƚĂŶĚĂƌĚ ƐƚĂŐŶĂƚŝŽŶ ƚĞŵƉĞƌĂƚƵƌĞ ;' с ϭϬϬϬ tͬŵϸ͖ ੥ a  = 30 °C)  ੥ ƐƚŐ  280  °C  W/m², expressed in % and rounded to the nearest integer.
                Effective thermal capacity, incl. fluid (per gross area, A G )  C/m 2  3,17  kJ/(Km 2 )   ĞǀŝĂƚŝŶŐ ĨƌŽŵ ƚŚĞ ƌĞŐƵůĂƚŝŽŶ ɻ col  is based on reference area
                Maximum operating temperature  ੥ ŵĂdžͺŽƉ  120  °C                           (A sol ) which is aperture area for values according to EN 12975-2
                Maximum operating pressure  Ɖ ŵĂdž͕ŽƉ  1000 ŬWĂ                             or gross area for ISO 9806:2013.
                Testing laboratory  dĞƐƚ>Ăď    -                                           Data required for CDR (EU) No 812/2013 - Reference Area A sol
                Test report(s)  131016040GZU-001  Dated  2014-01-07                        ĞƌŽͲůŽƐƐ ĞĨĨŝĐŝĞŶĐLJ ;ɻ 0  )  0,541  --
                                                                                           &ŝƌƐƚͲŽƌĚĞƌ ĐŽĞĨĨŝĐŝĞŶƚ ;Ă 1 )   1,21  W/(m²K)
                                                                                           ^ĞĐŽŶĚͲŽƌĚĞƌ ĐŽĞĨĨŝĐŝĞŶƚ ;Ă 2 )   0,004  W/(m²K²)
                Comments of testing laboratory   ĂƚĂƐŚĞĞƚ ǀĞƌƐŝŽŶ͗ ϱ͘Ϭϭ͕ ϮϬϭϲͲϬϯͲϬϭ        /ŶĐŝĚĞŶĐĞ ĂŶŐůĞ ŵŽĚŝĨŝĞƌ / D ;ϱϬΣͿ  0,00  --
                EĞŐĂƚŝǀĞ ŵĞĐŚĂŶŝĐĂů ůŽĂĚ ƚĞƐƚ ŽĨ ĐŽůůĞĐƚŽƌ ǁĂƐ ŶŽƚ ƉĞƌĨŽƌŵĞĚ               Remark: The data given in this section are related to collector
                                                                                           reference area (A sol ) which is aperture area for values according
                                                                                           to EN 12975-2  or  gross area for ISO 9806. Consistent data sets for
                                                                                           either aperture or gross area can be used in calculations like in the
                                                                                           regulation 811 and 812 and simulation programs.
                         Certification Body:   RISE Research Institutes of Sweden | Certification  Certification Body:   RISE Research Institutes of Sweden | Certification
                      Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.se  Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.se
              CERTIFICATO SOLAR KEYMARK                               CERTIFICATO SOLAR KEYMARK
            Per la documentazione completa consultare il sito www.solarkeimark.dk.
                                                          - 220 -