Page 220 - CORDIVARI - CATALISTINO SISTEMI SOLARI
P. 220
CERTIFICAZIONI DI PRODOTTO
CERTIFICATO SOLAR KEYMARK CERTIFICATO SOLAR KEYMARK
Annex to Solar Keymark Certificate Annex to Solar Keymark Certificate
Page 1/2 Page 2/2
Licence Number SC0140-18 Annex to Solar Keymark Certificate Licence Number SC0140-18
Annex to Solar Keymark Certificate - Summary of EN 12975-2
Date issued 2018-03-16 Supplementary Information Issued 2018-03-16
Test Results
Issued by RISE ŶŶƵĂů ĐŽůůĞĐƚŽƌ ŽƵƚƉƵƚ ŝŶ ŬtŚͬĐŽůůĞĐƚŽƌ Ăƚ ŵĞĂŶ ĨůƵŝĚ ƚĞŵƉĞƌĂƚƵƌĞ m , based on EN 12975-2 test results
Licence holder Cordivari S. R. L. Country Italy Standard Locations Athens Davos Stockholm Würzburg
Brand ;ŽƉƚŝŽŶĂůͿ sd Web ŚƚƚƉ͗ͬͬǁǁǁ͘ĐŽƌĚŝǀĂƌŝ͘ŝƚͬ Collector name m 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C
Street, Number ŽŶĂ /ŶĚƵƐƚƌŝĂůĞ WĂŐůŝĂƌĞ ʹ ϲϰϬϮϬ ŵŽƌƌŽ Ě͛ŽƌŽ E-mail ŝŶĨŽΛĐŽƌĚŝǀĂƌŝ͘ŝƚ sdϭϬ 1 998 1 716 1 435 1 682 1 418 1 171 1 212 992 796 1 304 1 069 854
Postcode, City dĞƌĂŵŽ Tel +39 085 80401 sdϭϱ 2 965 2 546 2 129 2 496 2 105 1 738 1 798 1 472 1 181 1 935 1 586 1 267
Collector Type ǀĂĐƵĂƚĞĚ ƚƵďƵůĂƌ ĐŽůůĞĐƚŽƌ
Power output per collector
'ď с ϴϱϬ tͬŵϸ͖ 'Ě с ϭϱϬ tͬŵϸ
Gross area (A G ) Gross length Gross width Gross height 0 K 10 K 30 K ŵ Ͳ Ă 50 K 70 K 64 K
Collector name m² mm mm mm W W W W W W
CVT10 2,17 1 917 1 130 133 1 175 1 147 1 088 1 021 947 970
CVT15 3,22 1 917 1 680 133 1 743 1 703 1 614 1 515 1 406 1 440
0 0 0 0 0 0
0 0 0 0 0 0 ŶŶƵĂů ŽƵƚƉƵƚ ƉĞƌ ŵϸ ŐƌŽƐƐ ĂƌĞĂ 921 791 661 775 654 540 558 457 367 601 493 393
0 0 0 0 0 0 &ŝdžĞĚ Žƌ ƚƌĂĐŬŝŶŐ ĐŽůůĞĐƚŽƌ &ŝdžĞĚ ;ƐůŽƉĞ с ůĂƚŝƚƵĚĞ Ͳ ϭϱΣ͖ ƌŽƵŶĚĞĚ ƚŽ ŶĞĂƌĞƐƚ ϱΣͿ
0 0 0 0 0 0 ŶŶƵĂů ŝƌƌĂĚŝĂƚŝŽŶ ŽŶ ĐŽůůĞĐƚŽƌ ƉůĂŶĞ ϭϳϲϱ ŬtŚͬŵϸ ϭϳϭϰ ŬtŚͬŵϸ ϭϭϲϲ ŬtŚͬŵϸ ϭϮϰϰ ŬtŚͬŵϸ
0 0 0 0 0 0 DĞĂŶ ĂŶŶƵĂů ĂŵďŝĞŶƚ Ăŝƌ ƚĞŵƉĞƌĂƚƵƌĞ 18,5°C 3,2°C 7,5°C 9,0°C
0 0 0 0 0 0 ŽůůĞĐƚŽƌ ŽƌŝĞŶƚĂƚŝŽŶ Žƌ ƚƌĂĐŬŝŶŐ ŵŽĚĞ ^ŽƵƚŚ͕ ϮϱΣ ^ŽƵƚŚ͕ ϯϬΣ ^ŽƵƚŚ͕ ϰϱΣ ^ŽƵƚŚ͕ ϯϱΣ
0 0 0 0 0 0 dŚĞ ĐŽůůĞĐƚŽƌ ŝƐ ŽƉĞƌĂƚĞĚ Ăƚ ĐŽŶƐƚĂŶƚ ƚĞŵƉĞƌĂƚƵƌĞ ŵ ;ŵĞĂŶ ŽĨ ŝŶͲ ĂŶĚ ŽƵƚůĞƚ ƚĞŵƉĞƌĂƚƵƌĞƐͿ͘ dŚĞ ĐĂůĐƵůĂƚŝŽŶ ŽĨ ƚŚĞ ĂŶŶƵĂů
0 0 0 0 0 0 ĐŽůůĞĐƚŽƌ ƉĞƌĨŽƌŵĂŶĐĞ ŝƐ ƉĞƌĨŽƌŵĞĚ ǁŝƚŚ ƚŚĞ ŽĨĨŝĐŝĂů ^ŽůĂƌ <ĞLJŵĂƌŬ ƐƉƌĞĂĚƐŚĞĞƚ ƚŽŽů ^ĐĞŶŽĐĂůĐ sĞƌ͘ ϱ͘Ϭϭ ;DĂƌĐŚ ϮϬϭϲͿ͘ ĚĞƚĂŝůĞĚ
0 0 0 0 0 0 ĚĞƐĐƌŝƉƚŝŽŶ ŽĨ ƚŚĞ ĐĂůĐƵůĂƚŝŽŶƐ ŝƐ ĂǀĂŝůĂďůĞ Ăƚ ǁǁǁ͘ƐŽůĂƌŬĞLJŵĂƌŬ͘ŽƌŐͬƐĐĞŶŽĐĂůĐ
0 0 0 0 0 0 Additional Information
0 0 0 0 0 0 ŽůůĞĐƚŽƌ ŚĞĂƚ ƚƌĂŶƐĨĞƌ ŵĞĚŝƵŵ tĂƚĞƌͲ'ůLJĐŽůĞ
0 0 0 0 0 0 ,LJďƌŝĚ dŚĞƌŵĂů ĂŶĚ WŚŽƚŽ sŽůƚĂŝĐ ĐŽůůĞĐƚŽƌ EŽ
Power output per m² gross area 541 529 501 471 437 447 dŚĞ ĐŽůůĞĐƚŽƌ ŝƐ ĚĞĞŵĞĚ ƚŽ ďĞ ƐƵŝƚĂďůĞ ĨŽƌ ƌŽŽĨ ŝŶƚĞŐƌĂƚŝŽŶ EŽ
Performance parameters test method ^ƚĞĂĚLJ ƐƚĂƚĞ Ͳ ŽƵƚĚŽŽƌ dŚĞ ĐŽůůĞĐƚŽƌ ǁĂƐ ƚĞƐƚĞĚ ƐƵĐĐĞƐƐĨƵůůLJ ĂĐĐŽƌĚŝŶŐ ƚŽ E /^K ϵϴϬϲ͗ϮϬϭϯ ƵŶĚĞƌ ƚŚĞ ĨŽůůŽǁŝŶŐ ĐŽŶĚŝƚŝŽŶƐ͗
Performance parameters (related to AG) ɻϬ͕ŚĞŵ a1 a2 ůŝŵĂƚĞ ĐůĂƐƐ ; ͕ Žƌ Ϳ C --
Units - W/(m²K) W/(m²K²) DĂdžŝŵƵŵ ƚĞƐƚĞĚ ƉŽƐŝƚŝǀĞ ůŽĂĚ 2860 WĂ
Test results 0,541 1,212 0,004 0,180 0,000 0,000 0,910 DĂdžŝŵƵŵ ƚĞƐƚĞĚ ŶĞŐĂƚŝǀĞ ůŽĂĚ - WĂ
,Ăŝů ƌĞƐŝƐƚĂŶĐĞ ƵƐŝŶŐ ƐƚĞĞů ďĂůů ;ŵĂdžŝŵƵŵ ĚƌŽƉ ŚĞŝŐŚƚͿ 0,8 m
Incidence angle modifier test method YƵĂƐŝ ĚLJŶĂŵŝĐ Ͳ ŽƵƚĚŽŽƌ
Bi-directional incidence angle modifiers zĞƐ Energy Labelling Information
Incidence angle modifier ŶŐůĞ 10° 20° 30° 40° 50° 60° 70° 80° 90° ZĞĨĞƌĞŶĐĞ ƌĞĂ͕ ƐŽů (m 2 ) Data required for CDR (EU) No 811/2013 - Reference Area A sol
Transversal K ɽd͕ĐŽůů 1,03 1,05 1,18 0,00 sdϭϬ 2,17 ŽůůĞĐƚŽƌ ĞĨĨŝĐŝĞŶĐLJ ;ɻ ĐŽů ) 49 %
Longitudinal K ɽ>͕ĐŽůů 0,95 0,00 sdϭϱ 3,22 ZĞŵĂƌŬ͗ ŽůůĞĐƚŽƌ ĞĨĨŝĐŝĞŶĐLJ ;ɻ col ) is defined in CDR (EU) No
Heat transfer medium for testing tĂƚĞƌ 811/2013 as collector efficiency of the solar collector at a
Flow rate for testing (per gross area, A G ) ĚŵͬĚƚ 0,020 ŬŐͬ;ƐŵϸͿ temperature difference between the solar collector and the
Maximum temperature difference for thermal performance calculations ; m Ͳ a ) max 64 K surrounding air of 40 K and a global solar irradiance of 1000
^ƚĂŶĚĂƌĚ ƐƚĂŐŶĂƚŝŽŶ ƚĞŵƉĞƌĂƚƵƌĞ ;' с ϭϬϬϬ tͬŵϸ͖ a = 30 °C) ƐƚŐ 280 °C W/m², expressed in % and rounded to the nearest integer.
Effective thermal capacity, incl. fluid (per gross area, A G ) C/m 2 3,17 kJ/(Km 2 ) ĞǀŝĂƚŝŶŐ ĨƌŽŵ ƚŚĞ ƌĞŐƵůĂƚŝŽŶ ɻ col is based on reference area
Maximum operating temperature ŵĂdžͺŽƉ 120 °C (A sol ) which is aperture area for values according to EN 12975-2
Maximum operating pressure Ɖ ŵĂdž͕ŽƉ 1000 ŬWĂ or gross area for ISO 9806:2013.
Testing laboratory dĞƐƚ>Ăď - Data required for CDR (EU) No 812/2013 - Reference Area A sol
Test report(s) 131016040GZU-001 Dated 2014-01-07 ĞƌŽͲůŽƐƐ ĞĨĨŝĐŝĞŶĐLJ ;ɻ 0 ) 0,541 --
&ŝƌƐƚͲŽƌĚĞƌ ĐŽĞĨĨŝĐŝĞŶƚ ;Ă 1 ) 1,21 W/(m²K)
^ĞĐŽŶĚͲŽƌĚĞƌ ĐŽĞĨĨŝĐŝĞŶƚ ;Ă 2 ) 0,004 W/(m²K²)
Comments of testing laboratory ĂƚĂƐŚĞĞƚ ǀĞƌƐŝŽŶ͗ ϱ͘Ϭϭ͕ ϮϬϭϲͲϬϯͲϬϭ /ŶĐŝĚĞŶĐĞ ĂŶŐůĞ ŵŽĚŝĨŝĞƌ / D ;ϱϬΣͿ 0,00 --
EĞŐĂƚŝǀĞ ŵĞĐŚĂŶŝĐĂů ůŽĂĚ ƚĞƐƚ ŽĨ ĐŽůůĞĐƚŽƌ ǁĂƐ ŶŽƚ ƉĞƌĨŽƌŵĞĚ Remark: The data given in this section are related to collector
reference area (A sol ) which is aperture area for values according
to EN 12975-2 or gross area for ISO 9806. Consistent data sets for
either aperture or gross area can be used in calculations like in the
regulation 811 and 812 and simulation programs.
Certification Body: RISE Research Institutes of Sweden | Certification Certification Body: RISE Research Institutes of Sweden | Certification
Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.se Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.se
CERTIFICATO SOLAR KEYMARK CERTIFICATO SOLAR KEYMARK
Per la documentazione completa consultare il sito www.solarkeimark.dk.
- 220 -