Page 624 - AERMEC - CATALOGO PRODOTTI 2024
P. 624

Ver              1600           1805            2006           2206            2406
                          A               T6NRB15         T6NRB15        T6NRB15        T6NRB15         T6NRB16
                          E,U             T6NRB15         T6NRB17        T6NRB16        T6NRB19         T6NRB19
                          N               T6NRB18         T6NRB19        T6NRB19        T6NRB20         T6NRB20

                 Il fondino grigio indica gli accessori montati in fabbrica
                 Griglie di protezione
                          Ver          0800   0900   1000   1100   1200   1400   1600   1805   2006   2206   2406
                          A           GP2VN  GP2VN  GP3VNF  GP3VNF  GP3VNF  GP3VNF  GP4VN  GP4G  GP5G  GP5G  GP6V
                          E,U         GP3VNF  GP3VNF  GP3VNF  GP4VN  GP4VN  GP4VN  GP5VN  GP6V  GP6V  GP7V   GP7V
                          N           GP4VN  GP4VN  GP4VN  GP5VN  GP5VN  GP5VN   GP6V   GP7V   GP7V   GP8V   GP8V
                 Il fondino grigio indica gli accessori montati in fabbrica
                 Le unità 0800A, 0900A con l'opzione "accumulo" hanno una lunghezza di
                 3970 mm, e devono montare le griglie GP2VNA.
                 DATI PRESTAZIONALI
                 NRB - A
                 Taglia                           0800  0900  1000  1100  1200  1400  1600  1805  2006  2206  2406
                 Modello: F
                 Prestazioni in raffreddamento funzionamento meccanico (1)

                 Potenza frigorifera         kW   211,8  234,3  273,4  307,1  335,9  373,3  432,0  474,2  542,2  584,4  655,6
                 Potenza assorbita           kW   76,0  88,0  93,9  108,9  124,8  145,6  157,1  185,1  201,0  229,4  243,7
                 Corrente assorbita totale a freddo  A  134,0  152,0  165,0  189,0  215,0  248,0  270,0  316,0  347,0  394,0  423,0
                 EER                        W/W   2,79  2,66  2,91  2,82  2,69  2,56  2,75  2,56  2,70  2,55  2,69
                 Portata acqua utenza        l/h  36397  40249  46968  52762  57713  64138  74217  81471  93153  100403  112635
                 Perdita di carico lato utenza  kPa  49  50   68    76    91    99    64    68    88    96    122
                 Prestazioni in raffreddamento funzionamento free-cooling (2)
                 Potenza frigorifera         kW   139,8  142,0  203,2  208,4  211,6  214,7  280,5  284,4  350,8  354,8  421,5    FREECOOLING
                 Potenza assorbita           kW   7,5   7,5   11,2  11,2  11,2  11,2  15,0  15,0  18,7  18,7  22,5
                 Corrente assorbita totale in free-cooling  A  13,0  13,0  20,0  20,0  19,0  19,0  26,0  26,0  32,0  32,0  39,0
                 EER                        W/W   18,64  18,94  18,07  18,53  18,81  19,09  18,71  18,97  18,72  18,93  18,74
                 Portata acqua utenza        l/h  36397  40249  46968  52762  57713  64138  74217  81471  93153  100403  112635
                 Perdita di carico lato utenza  kPa  88  97   101   117   139   158   112   125   144   161   188
                 (1)  Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C; Funzionamento meccanico 100%; Free-cooling 0%
                 (2)  Acqua scambiatore lato utenza 12 °C / * °C  ; Aria esterna 2 °C
                 Taglia                           0800  0900  1000  1100  1200  1400  1600  1805  2006  2206  2406
                 Modello: P
                 Prestazioni in raffreddamento funzionamento meccanico (1)
                 Potenza frigorifera         kW   210,3  232,4  271,9  305,1  333,3  369,6  428,9  469,8  538,2  579,2  650,8
                 Potenza assorbita           kW   76,8  89,2  94,8  110,0  126,2  147,6  158,7  187,5  203,2  232,3  246,6
                 Corrente assorbita totale a freddo  A  135,0  154,0  167,0  191,0  217,0  251,0  272,0  320,0  351,0  399,0  427,0
                 EER                        W/W   2,74  2,61  2,87  2,77  2,64  2,50  2,70  2,51  2,65  2,49  2,64
                 Portata acqua utenza        l/h  36136  39921  46723  52411  57266  63506  73697  80717  92472  99510  111819
                 Perdita di carico lato utenza  kPa  48  49   67    75    89    97    63    66    87    95    120
                 Prestazioni in raffreddamento funzionamento free-cooling (2)
                 Potenza frigorifera         kW   149,8  152,0  217,8  223,3  226,6  229,5  300,5  304,3  375,9  379,8  451,6
                 Potenza assorbita           kW   7,6   7,6   11,4  11,4  11,4  11,4  15,2  15,2  19,0  19,0  22,8
                 Corrente assorbita totale in free-cooling  A  13,0  13,0  20,0  20,0  20,0  19,0  26,0  26,0  33,0  33,0  40,0
                 EER                        W/W   19,66  19,95  19,06  19,55  19,83  20,09  19,73  19,98  19,74  19,94  19,76
                 Portata acqua utenza        l/h  36136  29921  46723  52411  57266  63506  73697  80717  92472  99510  111819
                 Perdita di carico lato utenza  kPa  86  95   100   116   137   155   110   123   142   158   185
                 (1)  Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C; Funzionamento meccanico 100%; Free-cooling 0%
                 (2)  Acqua scambiatore lato utenza 12 °C / * °C  ; Aria esterna 2 °C
                 NRB - E
                 Taglia                           0800  0900  1000  1100  1200  1400  1600  1805  2006  2206  2406
                 Modello: F
                 Prestazioni in raffreddamento funzionamento meccanico (1)
                 Potenza frigorifera         kW   220,6  242,6  265,3  310,3  344,7  379,2  438,5  498,2  546,9  610,1  652,9
                 Potenza assorbita           kW   73,4  84,2  95,7  106,6  122,4  142,0  155,3  174,8  199,2  219,5  244,7
                 Corrente assorbita totale a freddo  A  126,0  142,0  160,0  179,0  205,0  236,0  258,0  292,0  333,0  368,0  411,0
                 EER                        W/W   3,00  2,88  2,77  2,91  2,82  2,67  2,82  2,85  2,75  2,78  2,67
                 Portata acqua utenza        l/h  37902  41688  45573  53310  59226  65155  75344  85588  93960  104827  112169
                 Perdita di carico lato utenza  kPa  44  53   57    82    90    109   58    75    85    89    102
                 Prestazioni in raffreddamento funzionamento free-cooling (2)
                 Potenza frigorifera         kW   164,6  168,5  223,0  222,5  227,6  231,2  285,4  338,9  344,8  399,2  403,7
                 Potenza assorbita           kW   7,9   7,9   7,9   10,5  10,5  10,5  13,1  15,8  15,8  18,4  18,4
                 Corrente assorbita totale in free-cooling  A  13,0  13,0  13,0  18,0  18,0  17,0  22,0  26,0  26,0  31,0  31,0
                 EER                        W/W   20,90  21,39  21,78  21,18  21,67  22,02  21,74  21,51  21,89  21,72  21,97
                 Portata acqua utenza        l/h  37902  41688  45573  53310  59226  65155  75344  85588  93960  104827  112169
                 Perdita di carico lato utenza  kPa  67  80   88    120   136   165   95    114   132   139   159
                 (1)  Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C; Funzionamento meccanico 100%; Free-cooling 0%
                 (2)  Acqua scambiatore lato utenza 12 °C / * °C  ; Aria esterna 2 °C

             622                                            www.aermec.com                      NRB-0800-3600-FC_I_UN50_09
   619   620   621   622   623   624   625   626   627   628   629