Page 195 - IRSAP - CATAOGO 2024 - FIDRA
P. 195

GET UP AIR MIX





                                               446          554        138

                                      122                          Ø23
                 446
                               554

                                      Ø23
                                           1547        1499         1547
              1124        1076         1124





                               550                         550






           16
        EN442-1                                 Potenza Termica     Potenza
               Prof.                      ∆t=50°C  ∆t=40°C∆t=30°C∆t=20°C suppl. con
        Modello  Ap./Ch. Alt. Largh. Inter. Peso Cap.  Aperto/Chiuso  Ap./Ch. Ap./Ch. Ap./Ch.  Booster  Esp.
               P mm  H mm L mm L’ mm  Kg  lt  kcal/h  Watt  Watt  Watt (*)  Watt  Watt  n.
        1076
        20 tubi   385/122 1124  550  500  17,2  6,9 538/461 625/536 473/396 330/268 199/155  +1000  1,251
       1 intervallo
        1499
        25 tubi   385/122 1547  550  500  22,1  9,2 667/607 775/706 583/527 403/362 240/213  +1000  1,278
       2 intervalli

       ∆t=50°C  consigliato per caldaie tradizionali  ∆t=40°C  consigliato per caldaie a condensazione e pompe di calore
       ∆t=30°C  consigliato per pompe di calore
       • Pressione di esercizio massima ammessa 4 bar  DOTAZIONE DI SERIE:  3 fissaggi a muro; 1 valvola sfiato
       • Temperatura di esercizio massima ammessa 95°C  da 1/8” per radiatore modello M (altezza 1076 mm); 1
                                            valvola sfiato da 1/8” e 1 valvola sfiato da 1/2” per radiatore
       Colori disponibili: vedere tabella a pag. 280.  modello L (altezza 1499 mm).











 192                                      193