DATI PRESTAZIONALI UNITÀ INTERNA
                 LPG_D
                 Unità interna                   LPG350D  LPG500D  LPG700D  LPG850D LPG1000D LPG1000D LPG1200D LPG1200D LPG1400D LPG1400D LPG1600D
                 Unità esterna                    LPG350  LPG500  LCG700  LPG850  LPG1000 LPG1000T LPG1200 LPG1200T LPG1400 LPG1400T LPG1600T

                 Prestazioni in raffrescamento nominali
                 Potenza frigorifera (1)    kW    3,50  5,30  7,10  8,50  10,50  10,50  12,10  12,10  13,40  13,40  16,00
                 Potenza assorbita a freddo (1)  kW  1,03  1,51  1,92  2,50  3,00  3,00  3,58  3,58  4,50  4,50  5,40
                 EER (2)                    W/W   3,40  3,51  3,70  3,40  3,50  3,50  3,38  3,38  2,98  2,98  2,96
                 Umidità asportata          l/h    1,0   1,7   2,4  2,8   3,3   3,3   3,7   3,7   3,9   3,9   4,6
                 Prestazioni in raffrescamento minime
                 Potenza frigorifera        kW    0,90  1,60  2,40  2,90  3,20  3,20  3,60  3,60  4,00  4,00  4,80
                 Potenza assorbita a freddo  kW   0,20  0,30  0,50  0,75  0,90  0,90  1,10  1,10  1,35  1,35  1,50

                 Prestazioni in raffrescamento massime
                 Potenza frigorifera        kW    4,00  5,80  7,60  9,00  11,00  11,00  13,10  13,10  14,20  14,20  17,00
                 Potenza assorbita a freddo  kW   1,30  1,80  2,60  3,30  4,00  4,00  5,30  5,30  5,60  5,60  6,80
                 Efficienza stagionale
                 SEER                       W/W   6,50  6,30  6,60  6,40  6,40  6,40  6,10  6,10  6,10  6,10  6,10
                 Classe efficienza energetica (3)  A++  A++   A++   A++   A++   A++    -     -     -    -     -
                 Pdesignc                   kW     3,5   5,3   7,1  8,5   10,5  10,5   -     -     -    -     -
                 Consumo elettrico annuo  kWh/annum  189  294  377  465   574   574    -     -     -    -     -

                 Prestazioni in riscaldamento nominali
                 Potenza termica (4)        kW    4,00  5,60  8,00  8,80  11,50  11,50  13,50  13,50  15,50  15,50  17,00
                 Potenza assorbita a caldo (4)  kW  1,00  1,42  2,00  2,25  2,80  2,80  3,70  3,70  4,50  4,50  4,70
                 COP (2)                    W/W   4,00  3,94  4,00  3,91  4,11  4,11  3,65  3,65  3,44  3,44  3,62
                 Prestazioni in riscaldamento minime
                 Potenza termica            kW    0,90  1,60  2,20  2,50  3,00  3,00  3,60  3,60  3,90  3,90  4,50
                 Potenza assorbita a caldo  kW    0,20  0,30  0,50  0,75  0,90  0,90  1,10  1,10  1,35  1,35  1,50
                 Prestazioni in riscaldamento massime

                 Potenza termica            kW     4,50  6,10  8,60  9,50  12,50  12,50  14,50  14,50  16,00  16,00  18,00
                 Potenza assorbita a caldo  kW     1,30  1,80  2,60  3,30  4,00  4,00  5,30  5,30  5,60  5,60  6,80
                 Efficienza stagionale (clima temperato)
                 SCOP                       W/W    4,00  4,00  4,10  4,10  4,20  4,20  4,10  4,10  4,00  4,00  4,00
                 Classe efficienza energetica (3)  A+    A+    A+   A+    A+    A+     -     -     -    -     -
                 Pdesignh                   kW     3,00  3,90  4,70  6,00  7,00  7,00  -     -     -    -     -
                 Consumo elettrico annuo  kWh/annum  1050  1365  1605  2049  2333  2333  -   -     -    -     -

                 Dati elettrici
                 Potenza nominale assorbita (5)  kW  1,30  1,90  2,80  3,30  4,70  4,40  5,30  5,30  5,60  5,60  6,80
                 Corrente nominale assorbita (5)  A  6,0  9,5  14,0  15,0  21,0  7,0  23,0  9,0   25,0  11,0  12,0
                 Tubazioni frigorifere
                 Diametro attacchi frigoriferi liquido  mm (inch)  6.35 (1/4”) 6.35 (1/4”) 15.9 (5/8”) 15.9 (5/8”) 15.9 (5/8”) 15.9 (5/8”) 15.9 (5/8”) 15.9 (5/8”) 15.9 (5/8”) 15.9 (5/8”) 15.9 (5/8”)
                 Diametro attacchi frigoriferi gas  mm (inch)  9.52 (3/8”) 12.7 (1/2”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
                 Lunghezza nominale linee frigorifere  m  5,0  5,0  5,0  5,0  5,0  5,0  5,0  5,0  7,5   7,5   7,5
                 Alimentazione
                                                 220-240V ~  220-240V ~  220-240V ~  220-240V ~  220-240V ~  380-415V  220-240V ~  380-415V  220-240V ~  380-415V   380-415V
                 Alimentazione
                                                  50Hz  50Hz  50Hz  50Hz  50Hz  3N~ 50/60Hz  50Hz  3N~ 50/60Hz  50Hz  3N~ 50/60Hz3N~ 50/60Hz
                 (1)  Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
                 (2)  EER/COP in accordo alla Normativa (EN 14511), dichiarati solo al fine delle detrazioni fiscali in vigore all'atto della realizzazione di questa pubblicazione.
                 (3)  Dati in accordo con il regolamento delegato (UE) N.626/2011.
                 (4)  Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
                 (5)  La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
                                                  LPG350D  LPG500D  LPG700D  LPG850D  LPG1000D  LPG1200D  LPG1400D  LPG1600D

                 Unità interna
                 Tipo di ventilatore        Tipo  Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter
                 Portata d’aria
                 Turbo                      m³/h    600     900     1100    1400    1700    2000    2300    2600
                 Massima                    m³/h    550     800     1000    1300    1600    1800    2100    2300
                 Media                      m³/h    500     700     900     1100    1400    1600    1800    2000
                 Minima                     m³/h    400     600     800     1000    1200    1400    1500    1700
      SPLIT      Pressione statica utile    Pa      25      25      25      37      50       50      50      50              SPLIT
                 Nominale
                 Massima                    Pa      80      80      160     160     155     155     200      200
                 Pressione sonora
                 Turbo                      dB(A)  35,0     36,0    37,0    43,0    39,0    43,0    43,0    46,0
                 Massima                    dB(A)  33,0     35,0    35,0    41,0    38,0    42,0    42,0    44,0
                 Media                      dB(A)  32,0     33,0    33,0    39,0    37,0    41,0    40,0    42,0
                 Minima                     dB(A)  30,0     31,0    31,0    37,0    36,0    40,0    38,0    40,0
                 Unità interna

                 Diametro scarico condensa  mm     26,0     26,0    26,0    26,0    26,0    26,0    26,0    26,0
                 Pressione Sonora misurata in camera semi-anecoica a 1m di distanza dall'unità (1,5m per unità tipo Duct e Cassette)





                  LPG_I_UN50_02                             www.aermec.com                                          889