Page 546 - RIVER - CATALOGO 2022
P. 546

FAULT                           CAUSE                           REMEDY


              WALL MOUNTED MIXERS – all the models

                                                                               Non-stop
                                                                             supply ring

                                 Hot water                                    Cold water
                                 adjusting                                     adjusting
                                 and closing                                 and closing



                                          Cam with no-return valves
                                          and stainless steel filters


           non-satisfactory mixing          non-return valve is locked       the back pressure can lock one non-return valve
                                                                             of the mixer. It is necessary that the system is
                                                                             provided of traditional pressure shock absorber

              INFRARED WASHBASIN AND RECESSED SHOWER TAPS AND MIXER
              INFRARED RECESSED FLUSHOMETER Ø 3/4” FOR W.C.

           the fitting do not work and do not supply water  interception taps closed  open and adjust the flow rate of the stop-taps

                                                battery models               take away the plate and replace the battery
                                             empty battery and the LED blinks

                                                230V models                  check the power supply
                                             there is not power supply
                                             damaged transformer
                                                                             if the transfo rmer is well-run a  green LED is
                                                                             switch on, if the LED do not switch on replace
                                                                             the transformer

                                            electronic module do not work    replace the electronic module

           the fitting remain always open   magnetic valve blocked                           if the electronic car-
                                                                                             tridge result working,
                                                                                             wash carefully the ma-
                                                                                             gnetic valve










           the fitting supply few water    stainless steel filters are dirty  check the stainless steel filters of the taps and
                                                                             the magnetic valve filter

              INFRARED RECESSED URINAL                                          Scatola da incasso
                                                                                Recess-mounted box
                                                 Guarnizioni
                                                    Gaskets                     Rubinetto di chiusura
                                                                                Closing tap
                                            Raccordo Ø 1/2”
                                                 Threaded
                                             connection R 1/2”
                                                                                Elettrovalvola
                                                                                (controllare la freccia
                                                                                entrata e uscita)
                                                   Batteria                     Magnetic valve
                                                 alcalina 9V                    (check the inlet
                                                  9V alkaline                   and outlet arrow)
                                                    battery
                                              Coperchio con
                                            quadro elettronico
                                              Electronic board
                                                  assembly

           the fitting do not work and do not supply water     battery models  take away the plate and replace the battery
                                               empty battery and the red LED blinks
                                                 230V models there is not power supply  check the power suuply
                                              electronic module do not work

                                            interception taps closed         open and adjust the flow rate of the stop-taps
         546