Page 546 - RIVER - CATALOGO 2022
P. 546
FAULT CAUSE REMEDY
WALL MOUNTED MIXERS – all the models
Non-stop
supply ring
Hot water Cold water
adjusting adjusting
and closing and closing
Cam with no-return valves
and stainless steel filters
non-satisfactory mixing non-return valve is locked the back pressure can lock one non-return valve
of the mixer. It is necessary that the system is
provided of traditional pressure shock absorber
INFRARED WASHBASIN AND RECESSED SHOWER TAPS AND MIXER
INFRARED RECESSED FLUSHOMETER Ø 3/4” FOR W.C.
the fitting do not work and do not supply water interception taps closed open and adjust the flow rate of the stop-taps
battery models take away the plate and replace the battery
empty battery and the LED blinks
230V models check the power supply
there is not power supply
damaged transformer
if the transfo rmer is well-run a green LED is
switch on, if the LED do not switch on replace
the transformer
electronic module do not work replace the electronic module
the fitting remain always open magnetic valve blocked if the electronic car-
tridge result working,
wash carefully the ma-
gnetic valve
the fitting supply few water stainless steel filters are dirty check the stainless steel filters of the taps and
the magnetic valve filter
INFRARED RECESSED URINAL Scatola da incasso
Recess-mounted box
Guarnizioni
Gaskets Rubinetto di chiusura
Closing tap
Raccordo Ø 1/2”
Threaded
connection R 1/2”
Elettrovalvola
(controllare la freccia
entrata e uscita)
Batteria Magnetic valve
alcalina 9V (check the inlet
9V alkaline and outlet arrow)
battery
Coperchio con
quadro elettronico
Electronic board
assembly
the fitting do not work and do not supply water battery models take away the plate and replace the battery
empty battery and the red LED blinks
230V models there is not power supply check the power suuply
electronic module do not work
interception taps closed open and adjust the flow rate of the stop-taps
546