       MODELLO                           PFFY-P20VEM-E PFFY-P25VEM-E PFFY-P32VEM-E PFFY-P40VEM-E PFFY-P50VEM-E PFFY-P63VEM-E

       Alimentazione                                                  A 1 fase, 220-240V 50/60Hz
                                      kW      2.2         2.8         3.6         4.5         5.6         7.1
       Capacità di raffreddamento* 1
                                     Btu/h    7500        9600       12300       15400       19100       24200
                                      kW      2.5         3.2         4.0         5.0         6.3         8.0
       Capacità di riscaldamento* 2
                                     Btu/h    8500       10900       13600       17100       21500       27300
                         Raffreddamento  kW  0.021       0.026       0.031       0.037       0.054       0.061
       Potenza consumata
                         Riscaldamento  kW   0.021       0.026       0.031       0.037       0.054       0.061
                         Raffreddamento  A  0.26-0.25-0.24  0.31-0.30-0.29  0.37-0.35-0.34  0.39-0.38-0.36  0.58-0.56-0.55  0.52-0.50-0.48
       Corrente
                         Riscaldamento  A  0.26-0.25-0.24  0.31-0.30-0.29  0.37-0.35-0.34  0.39-0.38-0.36  0.58-0.56-0.55  0.52-0.50-0.48
       Finitura esterna                                 Galvanized steel plate, MUNSELL (1.0Y 9.2/0.2)/ABS, MUNSELL (5.32GY 8.75/0.37)
       Dimensioni AxLxP* 3            mm  669(726)x1142x217  669(726)x1142x217  669(726)x1142x217  669(726)x1342x217  669(726)x1342x217  669(726)x1542x217
       Peso netto                     kg      29.5        29.5        30          35          35         39.5
       Scambiatore di calore                                       Cross fin (Aluminum fin and copper tube)
                         Tipo x quantità  Ventilatore Scirocco x 2 Ventilatore Scirocco x 2 Ventilatore Scirocco x 2 Ventilatore Scirocco x 3 Ventilatore Scirocco x 3 Ventilatore Scirocco x 4
                                     m 3 /min  5.0 - 6.0 - 7.0  5.5 - 6.5 - 8.0  5.5 - 7.0 - 8.5  8.0 - 9.5 - 11.0  10.0 - 11.5 - 13.5  12.0 - 14.0 - 16.5
       Ventilatore       Portata d’aria  l/s  83 - 100 - 117  92 - 108 - 133  92 - 117 - 142  133 - 158 - 183  167 - 192 - 225  200 - 233 - 275
                                      cfm  177 - 212 - 247  194 - 230 - 282  194 - 247 - 300  282 - 335 - 388  353 - 406 - 477  424 - 494 - 583
                         Press. statica esterna  Pa  0    0           0           0           0           0
                         Tipo                                             DC motor
       Motore
                         Potenza resa  kW                                  0.096
       Filtro dell’aria                                          Tessuto a nido d’ape in polipropilene (lavabile)
       Diametro tubo     Gas (svasatura)  mm  12.7 (1/2) Brazed  12.7 (1/2) Brazed  12.7 (1/2) Brazed  12.7 (1/2) Brazed  12.7 (1/2) Brazed  15.88 (5/8) Brazed
       refrigerante      Liquido (svasatura)  mm  6.35 (1/4) Brazed  6.35 (1/4) Brazed  6.35 (1/4) Brazed  6.35 (1/4) Brazed  6.35 (1/4) Brazed  9.52 (3/8) Brazed
       Diametro tubo di scolo locale                                     O.D.32 (1-1/4)
       Pressione sonora              dB(A)  23.0-27.0-31.0  25.0-29.0-34.0  25.0-31.0-36.0  29.0-33.0-36.0  34.0-37.0-41.0  32.0-36.0-40.0
       1. Condizioni di raffreddamento nominali
       Interno: 27°C BS / 19°C BU, esterno: 35°C BS, lunghezza tubi: 7,5 m, dislivello: 0 m
       2. Condizioni di riscaldamento nominali
       Interno: 20°C BS, esterno: 7°C BS / 6°C BU, lunghezza tubi: 7,5 m, dislivello: 0 m
       3. I valori tra parentesi () mostrano l’altezza dell’unità con il supporto.
       * Per interventi su impianti, condutture, isolamento, cablaggio elettrico, alimentazione e altri oggetti, fare riferimento al manuale di installazione.
       * A causa dei continui miglioramenti, le specifiche sopra riportate sono soggette a modifica senza preavviso.
                                                                                                         s
                                                                                                      T’
                                                                                                WHA
                                                                                                WHAT’s
                                                                                              NEW
                                                                                              NEW
          Che cosa è cambiato nelle unità
          canalizzate PFFY-P VEM-E?

          •   Aggiunta la possibilità di installazione indipendente   •  Livelli sonori migliorati
          •  3 step di portata Bassa, Media, Alta            •  ModifIcato lo chassis e le dimensioni