                      FAULT                           CAUSE                           REMEDY


           Q KNEE OPERATED TAPS

           the tap remain always open or leak  blocked  tank,  foreign  body  under  the  flat   unscrew the cover under the handle and take
                                            washer, foreign body on the special washer  out the cartridge. Clean carefully the flat
                                                                             washer and the special washer. Reassemble
                                                                             the cartridge without put any grease inside. If
                                                                             the cartridge parts are worn-out, replace them
                                                                             with the “indivisible kit”

           water leakage undder the handle tap  pushbutton o-ring worn-out   take away the cartridge. Using an hexagonal
                                                                             pipe spanner 7 mm. Disassemble the stainless
                                                                             steel needle. Replace the pushbutton o-ring
                                                                             Ø 6,07x1,78

           Q PEDAL CONTROL
           the tap or the mixer leak        foreign body is on flat washer seal  dismount the tap or the mixer and clean carefully
                                                                             the flat washer seal of the mixing device.
                                                                             If the washer is worn out use the other side,
                                                                             rarely happen that this washer have to be
                                                                             replaced becaude the closing happen always
                                                                             softly
           the mixer supply water not sufficiently hot  the boiler temperature is too low, is lower than   carry the temperature of the water heater over
                                            40°C                             45°C
                                            hot water inlet filter is partially obstructed  clean the filter


                                            majority of cold water in the system  reduce the cold water flow rate at the inlet of
                                                                             the mixer
           Q INFRARED CONTROL WITH BATTERY

           the fitting do not work and do not supply water  empty battery    dismount  the  tight-ness  box  and  replace  the
                                                                             battery

           the fitting remain always open   magnetic valve blocked                           if  the  electronic  car-
                                                                                             tridge result working,
                                                                                             wash carefully the
                                                                                             magnetic valve